Pool related areas are deemed corrosive environments because of the pool sanitation chemicals that are used and stored there.
Swimming pool light electrical code.
Light sources within 10 feet of the edge of the pool or spa exception made for devices higher than 5 feet over the water level.
Due to the nature of the moist pool environment all equipment must be ul listed to withstand these types of environments.
All electrical outlets light switches and receptacles must be ul listed for safety assurance.
2017 national electrical code sps 316.
National electrical code definition are those pools that are constructed or partially in the ground all others pools capable of holding water with a depth greater than 42 inches.
10 horizontal from the pool wall.
Utility power lines that run over a pool or spa must be at least 22 5 feet above the water level or base of a diving platform.
2008 national electrical code 2010 residental code of new york state permanently installed swimming pools.
Cord length for a pump motor is 3 except for storable pools.
Electrical equipmentand wiring and installation including the grounding of pool components shall conform to chapter 27 electrical nfpa 70.
1 pool pump receptacle outlet and wiring methods a.
Published in august 2015 for decades the national electrical code nec prohibited underground wiring to be located under a pool and wiring for lighting fixtures in the zone that extends 5 feet horizontally from the inside wall of a pool.
Electrical outlet receptacles near swimming pools receptacles for motors and pumps must be protected by a gfci and are required to be located within 6 to 10 feet of the pool walls.
Swimming pool wiring nec article 680.
The 2011 revision changed 680 21 c to include 208v by replacing the or with through.
Swimming pool wiring nec article 680.
680 5 gfci s may be either circuit breakers or receptacle type.
Underwater lightingshall utilize transformers and low voltage circuits with each underwater light being grounded.
The national electrical code article 680 20a1 states that a pool light fixture over 15 volts must be gfci protected.
Which includes all grounding and bonding terminals such as grounding conductor terminals and circulation pump motors.
The very reason the original gfci circuit breaker tripped indicates that there is something wrong with the circuit and the gfci circuit breaker was providing the protection against a potential electric shock.
The 2008 nec added a requirement for pool motors to have gfci protection whenever they re rated 120v or 240v 15a or 20a.